The Fireman’s Guide to Main Street: The Old House

A five part series by
Lex Shady & Chris Tobin

This will be a five part series exclusively examining five different types of legacy construction, each with its own article as it pertains to firefighting. The types of buildings were selected based on their prominence in today’s main streets and historic districts. These specific types of buildings exist in small towns from coast to coast but are more commonly found East of the Mississippi River where our national building stock originated before moving Westward. The five buildings are the old house, the taxpayer, the old mill, the vacant theater, and the bowling alley. Today we examine...

Part 01: The Old House

The Building 
The older single family homes in historic districts and around Main streets come in a countless styles and forms. From large ornate Victorians that line avenues from early prominent landowners to small shotgun bungalows within walking distance to factories facilitating the local workforce. The majority of what we see today are legacy framed or masonry brick buildings dating from the 1850s-1930s. Due to their abundance and because the other buildings in this series are all commonly of masonry construction, this section will address specifically wood framed houses. Access to railroads for Eastern timber played a pivotal role in how early or late your areas legacy building stock will be. A towns layout also determined what type of structure would be built. Long narrow urban  lots would be best suited for gable front or shotgun style houses while wider ones would accommodate “ I-Houses” two rooms wide and one room deep. Most legacy frame houses were multi story with half storied gable windows or dormers of some sort. These buildings are easily identified from the exterior by stone foundations, center chimneys, wood siding, transoms, long narrow windows, metal roofs and upper floor window AC units are common due to subpar centralized air. 

2.jpg

The Hazards 
The inherent architectural hazards in old legacy homes starts in the framing. With access to timber and saw mills these “mass planned” homes went up fast with balloon framing techniques taking the place of rough cut post and beam. The fire spread in balloon framing is nothing new to firefighters. The continuous stud bay existing from basement to attic created a direct avenue of fire extension that would blow past floors of unsuspecting occupants and the unprepared fireman. Balloon framing ended in the 1940s for today’s platform framing. The classic indicators of balloon framing are, long stacked windows sharing the same stud bay, stone foundation and center chimney placement. Beware of modern additions to the exterior of these houses such as garages or sun rooms. This will create an interior balloon framed wall that was originally an outside one.

In addition to the framing voids created, legacy homes contained older lumber.. Go into an old attic and rub your finger on a ceiling joist, what you’ll see on your hand appears to be like charcoal dust. The structural members in these places are subject to what’s called pyrophoric carbonization. The wood is slowly oxidizing, losing moisture and thus burns more intensely due to lower ignition temperatures than expected. Many a fire has been started by a lightbulb being hung to close to a century’s old piece of lumber. 

The layouts of these homes present some challenges to firemen. Two sets of stairs would be common, one main set near the entrance and smaller set in the rear off the kitchen called “servants stairs”. A common roof style is the “ saltbox or catslide” depending on your region, which poses a significant upper floor fire spread potential via the roof soffit. Many also forget traditional buildings have 6 sides of fire spread. 4 walls, a floor and ceiling. A wood framed building has 7 since its exterior is entirely combustible. Keep this in mind concerning exposure protection and auto extension from windows lapping upwards against wood siding  into soffits. 

In addition some lesser known hazards are pocket doors, window transoms, laundry chutes, tin ceilings, metal roofs and combustible varnished wall coverings are all things to be cognizant of during firefighting operations. 

The Playbook 
Three words, hold the stairs! These buildings are almost always multiple stories with the bedrooms up stairs. The stairs and egress paths must be your strategic priority, fire heat and smoke will naturally be drawn up the stairs and into the sleeping areas above. If there are servants stairs this task will be doubled but no less important. Keep an eye out for a side entrance, these were common and offered access to the basement and second floor stairs from one location. The 1st line off must address this without delay. Anytime paused outside is more time the upper floors are filling with deadly byproducts of combustion. Confinement is key in legacy wood framed houses, search teams need to be aggressively diligent in getting above and ahead of hose lines if conditions permit in order to close doors and start overhaul concurrently with fire attack. Keep in mind if you VES and close the door for confinement there may be a failed transom window above, a high scan with a TIC should address this.

  Ventilation in these buildings should play off the compartmented nature of their design. This means hydraulic ventilation by the hose team will be much more effective than the wide area floor plans seen in modern homes. This also allows extinguishment, overhaul and ventilation to be done simultaneously with one or two crews in the area of origin. Careful with PPV early on as the many voids will give way to some very undesirable conditions. Fans should be used only in conjunction with overhaul well after the fires under control. Due to the prevalence of hip and gabled roofs, vertical ventilation is a common tactic for top floor fires containing knee walls. Understand you're venting voids not living space. 

Since these buildings are compartmentalized by design a single 1.75 hose line flowing 150gpm will do considerable knockdown to multiple rooms or even multiple floors of fire. Even so, as a regular precaution a second line should be put advanced to the upper floors for cutting off extension. This line can be dry stretched initially to get it in place quicker to upper floors. 

Maneuverability wins the day in these buildings. If conditions require a large amount of water on arrival, choose the deck gun before the 2.5 if possible. Trying to advance a large diameter line to upper floors inside a building with numerous small rooms creating corners will be futile. A well off fire will out pace your advance regardless of your available GPM. Save the 2.5 for defensive operations or exposure protection. 

4.jpg

Once the main body of fire is knocked, overhaul needs to start in 2 places as simultaneously as possible. Once in the room of origin and the bathroom or kitchen closest to the fire. Plaster and lath walls and ceilings are common and need to be overhauled appropriately by working the connections along a stud, rafter or joist. Kitchens and bathrooms are important to immediately check due to the presence of “wet walls” or the wall that contains the plumbing and vents creating a pipe chase. These walls are even more important when they’re directly above the fire floor or any fire in the basement. A general rule of thumb for overhauling in legacy construction is fire in the floor, open the wall. Fire in the wall, open the ceiling. Fire in the ceiling, open the baseboards on the floor above. These are fires you must stay ahead of by understanding where they’re going before it gets there. This forward thinking is the difference between evacuation tones and a quickly extinguished fire. 

The Short Staffed Response 
The initial response to an “old house” fire for a small department includes the same actions as that of an urban department. The initial attack line gets stretched, water is pumped, and command is established. Where it has the potential to get complicated is when your initial response consists of anywhere from 2-6 personnel. If your initial response does not have adequate manpower to complete tasks safely, your attack choices are made for you until additional personnel arrive. The only exception to this rule is for rescues, with confirmed or suspected entrapment, departments must search.

As we talked about before protecting the stairs can make or break how quickly you beat the fire. With low man power you may have to make an educated guess as to where the fire is, and make a choice as to which set of stairs to protect. Another line must be stretched to the second set of stairs as soon as manpower allows. The wrong choice can have dire consequences, so understanding fire behavior and fire spread in your old homes is extremely important.

5.jpg

Then there are the “other” tasks that must be completed at every fire. Manpower and the scene will dictate the tasks that are prioritized. Officers must be capable of reading fire behavior, and be able to quickly and correctly prioritize tasks across their members. Understanding the construction of the homes in your district will help you with these decisions. It is imperative that officers know their crews strengths and weaknesses and assigns tasks appropriately.

Without the luxury of having specific companies your members will need to be cross trained and capable of completing all of the tasks a fire requires. Frequently, members will be responsible for more than one task. An example of this could be your initial attack team also completing the primary search. Nozzle man focuses on the fire, and the second man quickly searches rooms and closes doors as they advance. Engineers must be comfortable pumping tank water to the first line, and then establishing their own water supply. Communication and speed are crucial.

Pre-planned mutual aid agreements may be beneficial. Having mutual aid departments automatically dispatched to your fires allows the officer to focus on the fire in front of them instead of worrying about what resources he or she will need to request from mutual aid - help is already coming. Recall for members and mutual aid from surrounding departments can take anywhere from 5-20 minutes on a good day, which is great for manpower on longer scenes, but doesn’t help for initial response tactics. You’ll still need them though, as you’ll need to provide your members with a chance to rest.

Old house fires also come with the potential for it to be a rural fire which adds an entirely new set of complications. Rapid response and establishing adequate water supply early, are the keys to success for these scenes. This is where pre-planning of your district is extremely important. The officer and driver must be aware of where the closest hydrant or dry hydrant is, and be able to rapidly establish a tanker shuttle if necessary. Tank water can get you a long way, but with delayed response due to travel times, it may not be enough. Don’t be afraid to call for help. It’s better to have too many on scene and send them home, than not enough. You can’t put out a fire if you run out of water.

Regardless of department size or response legacy wood framed buildings require strategic foreseeability on arrival. A wood framed building and its 7 sides of fire spread have been the thorn in many a Chiefs side. These old houses that exist in every small town in every state demand a certain level of respect thats been lost to modern lightweight construction in the name of a penny. These homes were built to last and will test every skill set a firefighter claims to have. Never forget the reality that no matter how much you know, where you work or how good you think you are the simple fact remains, the building does not care.